The H.B. Ross Manufacturing Company is proud to present the
The ACVGD Ross Meter answers the trouble crew’s question, “We know the underground secondary has failed but where do we dig?” With the Ross Meter, the operator can locate an underground secondary cable fault in as little as 15 minutes without disconnecting anything at the site or connecting anything else to the cable. The Ross Meter uses the AC voltage gradient already present in the soil to lead the operator directly to the fault.
A Complete and Easy-to-Carry Device
The Ross Meter, also known as the ACVGD, is an AC voltage gradient detector which locates direct buried secondary cable faults. Since 1975, linemen have trusted the Ross Meter to quickly, effectively and safely locate these types of faults. The ergonomically designed Ross Meter reduces risks of electrical contacts and any temptation to cut corners. With 30 second setup and teardown times, it’s the industry leader for speed and efficiency when answering trouble calls concerning circuits with direct buried secondary cable faults. This unit can handle up to 300 volts AC and will sense as little as 25 mV in the ground.
View Operation Manual | View Datasheet | View How-to Videos | Find a Dealer

| Feature | ROSS METER | H.J. Arnett Pinpointer HJA-471 | TIMCO Spitfire 300801 | Vivax VM-510FFL+ w/ A Frame |
|---|---|---|---|---|
| Typical Time to Locate Fault | 15 minutes or less* | Not published | Not published | Not published |
| Setup / Teardown | Approx. 30 seconds. No alterations at the site is required | Transmitter setup required – Cable isolation (>80v) | Meter removal may be required – Transmitter is connected to faulted conductor | Cable isolation & ground-bond preparation required then Transmitter setup required |
| External Transmitter Required | NO | Yes | Yes | Yes |
| Connection to Faulted Cable Required for Locating | NO | Yes | Yes | Yes |
| Injects a Locating Signal Into the Cable | NO | Yes | Yes | Yes |
| Uses the Fault’s Existing AC Leakage Signal | YES | No | No | No |
| Separate Transmitter Power Required | NO. None required | Yes | Yes | Yes |
| Primary Locating Equipment | Meter + 2 Probes | Transmitter + Receiver/Probes + Leads | Transmitter + Detector + Probes + Leads | Transmitter + A-Frame/Receiver + Leads |
| One-Person Operation | YES | Yes | Yes | Yes |
| Must Know Exact Cable Route Before Locating | NO | No | No | No — also provides cable tracing |
| High-Voltage Locating Pulse | NONE | Up to 2,500 VDC pulses | Approx. 960 VDC nominal pulses | Signal supplied by compatible transmitter |
| Direct-Buried Secondary Fault Location | YES — Purpose-Built | Yes | Yes | Yes |
| Digital Cable Depth / Tracing Capability | Not Required | No | No | Yes |
| Locating Philosophy | Detect what the fault is already producing | Create an artificial fault signal | Create an artificial fault signal | Create and trace an artificial fault signal |
| Field Advantage | Arrive. Probe. Locate. | Active high-energy fault locating | Active high-energy fault locating | Advanced digital locating and tracing |
| Approx MSRP | $2130 | ~$2,300 | ~$5,000 | ~$1640 |
The Ross Meter is a passive AC voltage-gradient detector (ACVGD). It does not require a transmitter to be connected to the faulted conductor and does not inject a locating signal into the cable.
Instead, it detects the electrical leakage already entering the earth from a direct-buried secondary cable fault and guides the operator to the location of the fault within minutes – something no other detector can do.
No transmitter.
No cable connection.
No complicated menus.
No elaborate setup.
Find the fault and get the customer’s power restored.
Approximately 30 Seconds to Set Up.
Typically Locate the Fault in 15 Minutes or Less.*
*HB Ross Manufacturing states that operators familiar with the Ross Meter typically locate qualifying direct-buried secondary cable faults within 15 minutes or less after arrival. Actual fault-location time varies depending on fault type, soil conditions, cable configuration, operator experience and other site conditions.
Competitive information is based on publicly available manufacturer literature and documentation. Product specifications and procedures may change. No comparable manufacturer-published average fault-location time was found for the competing products shown. MSRP is approximate – call a dealer for an accurate quote.
Our Main Goal is to Keep Operators Safe.
Achieve Maximum Productivity.
Maximum Return on Investment.
Preservation of Resources.